1.       MAJOR FACTORS OF PLANNING

1. Incineration Capacity

1)       Nameplate Capacity

The plant shall have an incineration capacity over 20 t/8 hours, when the

quality of refuse is within the specified range.

2)       Physical Properties of Refuse

(1)    Type of Refuse

Mixture of general refuse/kitchen refuse and combustible large sized

refuse.

(2)    Refuse Composition

As in the following page.

(3)    Elementary Contents in Combustible Refuse

 

2.       Number of Furnace

10 t/8 hours×2 Furnaces

3.       Type of Furnace

Batches incineration by Fluidized bed type incenerator

4.       Combustion Gas Cooling System

By water spraying.

5.       Furnace Operating Hours

8 hours per day.

6.       Furnace Operating System

This combustor shall be operated in the one-furnace-one-train mode.

  Refuse Receiving and Charging Facility

      Pit and Crane System (Manual)

  Combustion Facility

      Fluidized-bed Furnace

  Flue Gas Treatment Facility

      Filter-type Dust Collector

  Water Supply Facility

      City Water

  Waste Water Treatment Facility

    High-temperature Oxidation Treatment System (for waste water from the

    refuse pit) 

  Fan Facility

    Forced Draft Fan (FDF) and Induced Draft Fan (IDF)

  Ash Discharge Facility

    By Bunker

7.       Combustion Conditions

1) Furnace Temperature

  Combustion Chamber Outlet Temperature850950

8.       Pollution Control Standard

9.       1) Standard Composition of Flue Gas (0, 10O2, 1 atm, dry base)

 

                            Dust                                                           30 mg/Nm3    max.

                            Opacity                                                      10           max.

                            HCl                                                            40ppm             max.

                            SOX (as SO2)                                             100ppm           max.

                            NOX(as NO2)                                             150ppm           max.

                            CO                                                             100ppm           max.

                            Pb                                                              1.0mg/Nm3      max.

                            Cd                                                              0.2 mg/Nm3     max.

                            Hg                                                              0.2 mg/Nm3     max.

                            Ignition Loss of Ash                                   5                  max.

 

2)       Noise Level

The noise level shall be as below at the site boundary, when all furnaces are in operation at the rated load

Time Range

Noise Level (d BA)

Remarks

Morning/Evening

Below 65

AM5:00-AM7:00,PM8:00-PM11:00

Day Time

Below 75

AM7:00-PM8:00

Night Time

Below 55

PM11:00-AM5:00

 

 

3)       Vibration

4)       The vibration level shall be as below at the site boundary, when all furnaces are in operation at the rated load

Time Range

Vibration (decibel)

Day Time

Not applicable

Night Time

Not applicable

 

    6.  Fluidized Bed

        Media UsedType                                                Oribin sand No.4

                    Average Particle Size                      0.6mm

                    True Specific Gravity                       3.2

                    Nominal Specific Gravity                 1.5

                    Fluidizing Start Velocity                   0.2 m/s (20)

        Thickness                                                                0.8 m

        Space Velocity                                                        0.3 Nm/s

        Furnace Bed Load                                                  450 Kg/m2h

        Fluidizing Air Rate                                                   3,140 Nm3/h

                                                           (In case of design load refuse)

        Air Temperature                                                      28

 

7.       Combustion Chamber

Excess Air Rate                                                              1.8

Combustion Chamber Heat Load                                    81,800 Kcal/m3h

                                      (In case of design load refuse)

        Furnace Temperature Control System

Temp. Range

Control System

Over   900

Refuse feed reduce

Over   880

Water Spraying

Below  850

Igniting Burner

                                                                                      

8.       Furnace Temperature

Fluidized Bed                                                                  650 ~ 700

Combustion Chamber                                                     850 ~ 950

9.       Ignition Loss of Residues

Ignition Loss Below 5

10.   Design Basis for Prevention of Plooution

1)       Flue Gas Standard Value (0, 10O2, 1 atm, dry base)

 

                            Dust                                                           30 mg/Nm3    max.

                            Opacity                                                      10           max.

                            HCl                                                            40ppm             max.

                            SOX (as SO2)                                             100ppm           max.

                            NOX(as NO2)                                             150ppm           max.

                            CO                                                             100ppm           max.

                            Pb                                                              1.0mg/Nm3      max.

                            Cd                                                              0.2 mg/Nm3     max.

                            Hg                                                              0.2 mg/Nm3     max.

 

2)       Design Basis for Noise

The noise level shall be as below at the site boundary, when all furnaces are in operation at the rated load

Time Rang

Design Basis (dBA)

Remarks

Morning/Evening

Below 65

AM5:00-AM7:00,PM8:00-PM11:00

Day Time

Below 75

AM7;00-PM8:00

Night Time

Below 55

PM11:00-AM5:00

 

3)       Design Basis for Vibration

The vibration level shall be as below at the site boundary, when all furnaces

are in operation at the rated load

Time Rang

Design Basis

Day Time

Not applicable dB

Night Time

Not applicable dB

 

 


 

Fluidized Air Blower Design Calculations

 

1.   Fluidized air volume required:

= (fluidized bed area) ´ (design air velocity = 0.275 m/s @ 0.3 m/s) ´ 3,600

= (2.907 m2) ´ (0.3 m/s) ´ 3,600 sec/hr = 3,140 Nm3/hr

 

2.   Air volume design safety allowance factor = 1.2

      Required air volume:

      = 3,140 Nm3/hr ´ 1.2 ¸ 60 = 62.8 Nm3/min

      = 62.8 Nm3/hr ´ (273 + 28) ¸ 273 = 69.2 m3/min (at 28 °C)

 

3.   Design duct air velocity = 12 m/sec

      Required duct diameter:

      = 69.2 m3/min ¸ (60 ´ 12) = 0.096 m2

      = (0.096 ´ 4 ¸ p)0.5 = 0.35 m @ 400 mm

 

4.   Design pressure drops:

      = estimated nozzle pressure drops + estimated duct work pressure drops

      = 1,556 + 30 = 1,586 mmAq

 

5.   Pressure drops design safety allowance factor = 1.35

      Required pressure drops = 1,586 ´ 1.35 = 2,141 mmAq @ 2,200 mmAq

 

6.   Design blower efficiency = 70%

      Required blower power:

      = 69.2 m3/min ´ 2,200 mmAq ¸ (6,120 ´ 0.7) = 35.5 kw @ 40 kw

 

 

 

 